My colleague and I wrote this paper for the International Conference on Nuclear Engineering, winning the Student paper competition with it. A revised copy has been submitted for review to be published in ASME’s Nuclear Engineering and Radiation Science inaugural issue.
High Efficiency Gamma-Beta Blind Alpha Spectrometry for Nuclear Energy Applications
Jul 11, 2014
Citation
Webster, J. A., Hagen, A., Archambault, B. C., Hume, N., & Taleyarkhan, R. (2014). High Efficiency Gamma-Beta Blind Alpha Spectrometry for Nuclear Energy Applications. In Proceedings of the International Conference on Nuclear Engineering (p. V005T17A054). ASME. doi:10.1115/ICONE22-30821
Abstract
A novel, Centrifugally Tensioned Metastable Fluid Detector (CTMFD) sensor technology has been developed over the last decade to demonstrate high selective sensitivity and detection efficiency to various forms of radiation for wide-ranging conditions (e.g., power level, safeguards, security, and health physics) relevant to the nuclear energy industry. The CTMFD operates by tensioning a liquid with centrifugal force to weaken the bonds in the liquid to the point whereby even a femto-scale nuclear particle interactions can break the fluid and cause a detectable vaporization cascade. The operating principle has only peripheral similarity to the superheated bubble chamber based superheated droplet detectors (SDDs); instead, CTMFDs utilize mechanical “tension pressure” instead of thermal superheat offering a lot of practical advantages. CTMFDs have been used to detect a variety of alpha and neutron emitting sources in near real-time. The CTMFD is selectively blind to gamma photons and betas allowing for detection of alphas and neutrons in extreme gamma/beta background environments such as spent fuel reprocessing plants or under full power conditions within an operating nuclear reactor itself. The selective sensitivity allows for differentiation between alpha emitters including the isotopes of Plutonium. Mixtures of Plutonium isotopes have been measured in ratios of 1:1, 2:1, and 3:1 Pu-238:Pu-239 with successful differentiation. Due to the lack of gamma-beta background interference, the CTMFD’s LLD can be effectively reduced to zero and hence, is inherently more sensitive than scintillation based alpha spectrometers or SDDs and has been proven capable to detect below femtogram quantities of Plutonium-238. Plutonium is also easily distinguishable from Neptunium making it easy to measure the Plutonium concentration in the NPEX stream of a UREX reprocessing facility. The CTMFD has been calibrated for alphas from Americium (\( 5.5\,\mathrm{MeV}\)) and Curium (\( ∼ 6\,\mathrm{MeV}\)) as well. The CTMFD has furthermore, recently also been used to detect spontaneous and induced fission events which can be differentiated from alpha decay allowing for detection of fissionable material in a mixture of isotopes. This paper discusses these transformational developments which are also being entered for real-world commercial use.